Valve-in-valve TAVI outperforms repeat SAVR for in-hospital mortality
Ngày 23/02/2022 03:48 | Lượt xem: 743

Valve-in-valve transcatheter aortic valve implantation (TAVI) was associated with lower in-hospital mortality, but higher 30-day and six-month all-cause readmission than repeat surgical aortic valve replacements (SAVR) in patients with a failed aortic bioprosthetic valve.

This is according to the findings of a retrospective cohort study, published in the February issue of EuroIntervention, in which Monil Majmundar (Maimonides Medical Center, New York, USA) and colleagues compared valve-in-valve TAVI and repeat SAVR using data from 2016 to 2018 taken from the Nationwide Readmission Database.

The study’s primary outcomes were all-cause readmission at both 30 days and six months and in-hospital death. Secondary outcomes included in-hospital stroke, pacemaker implantation, 30-day or six-month major adverse cardiac events (MACE), and mortality during readmission.

The study report that, out of 6,769 procedures recorded during the study period, 3,724 (55%) patients underwent valve-in-valve TAVI, and 3,045 (45%) underwent repeat SAVR. Valve-in-valve TAVI was associated with lower in-hospital all-cause mortality (odds ratio [OR] 0.42, 95% confidence interval [CI]: 0.20–0.90, p=0.026) and a higher rate of 30-day (hazard ratio [HR] 1.46, 95% CI: 1.13–1.90, p=0.004) and 6-month all-cause readmission (HR 1.54, 95% CI: 1.14–2.10, p=0.006) compared with repeat SAVR. All secondary outcomes were comparable between the two groups.

The results led the study team to conclude that valve-in-valve TAVI is associated with lower in-hospital mortality, but higher 30-day and six-month all-cause readmission. However, they add that there was no difference between the two procedures in the risk of in-hospital stroke, post-procedure pacemaker implantation, MACE and mortality during 30-day and six-month readmission compared with repeat SAVR.

These findings, the authors suggest, indicate that valve-in-valve TAVI “can be performed safely in carefully selected patients”.

Source CardiovascularNews

Duc tin CLinic

Print Chia sẽ qua facebook bài: Valve-in-valve TAVI outperforms repeat SAVR for in-hospital mortality Chia sẽ qua google bài: Valve-in-valve TAVI outperforms repeat SAVR for in-hospital mortality Chia sẽ qua twitter bài: Valve-in-valve TAVI outperforms repeat SAVR for in-hospital mortality Chia sẽ qua MySpace bài: Valve-in-valve TAVI outperforms repeat SAVR for in-hospital mortality Chia sẽ qua LinkedIn bài: Valve-in-valve TAVI outperforms repeat SAVR for in-hospital mortality Chia sẽ qua stumbleupon bài: Valve-in-valve TAVI outperforms repeat SAVR for in-hospital mortality Chia sẽ qua icio bài: Valve-in-valve TAVI outperforms repeat SAVR for in-hospital mortality Chia sẽ qua digg bài: Valve-in-valve TAVI outperforms repeat SAVR for in-hospital mortality Chia sẽ qua yahoo bài: Valve-in-valve TAVI outperforms repeat SAVR for in-hospital mortality Chia sẽ qua yahoo bài: Valve-in-valve TAVI outperforms repeat SAVR for in-hospital mortality Chia sẽ qua yahoo bài: Valve-in-valve TAVI outperforms repeat SAVR for in-hospital mortality Chia sẽ qua yahoo bài: Valve-in-valve TAVI outperforms repeat SAVR for in-hospital mortality

Tin tức liên quan

CUSTOMER REVIEWS

  • I am Nguyen Thanh Sang, born in 1990. Since the examination and treatment at the clinic Duc Tin, I am very grateful to the Doctor for explaining and sharing about my illness. During the treatment time in the clinic I was very caring staff of the clinic. Now my illness has improved in a good way. Expect more and more clinic to be able to save many patients.

    I sincerely thank you !. Tel: 0938303275

  • Huynh Thi Muoi, born in 1940, was examined and treated at Duc Tin Clinic. I am very pleased about how to serve and care patients of the clinic. The doctor is committed to explaining and sharing with the patient.

    Huynh Thi Muoi sincerely thank you! Phone number: 0972868746

  • As I said Duc Tin surgical clinin is where my family trust, hope to visit. Physicians caring, thoughtful, gentle to the patient. Nurses and staff clinic polite, cheerful and thoughtful. This clinic clean, sterile, so I would love to. Tel: +84949914060.

  • The doctor is very caring, attentive and very gentle nurse, courteous, affable with me. The clinic is clean, comfortable, polite. I enjoyed this faith. Every visit I was very relieved disease. Tel: 0839820792.

  • I was patient, had to clinics of Dr. Le Duc Tin. I see very conscientious doctor patient care, answer any questions and very dedicated staff from the receptionist to the children tested, nursing. Clinics very clean and spacious. I'm very satisfied. Tel: +841227880829.

Search
Customer support

    Phone: (028) 3981 2678
    Mobile: 0903 839 878 - 0909 384 389

TOP