Ross procedure “associated with better long-term outcomes” for aortic valve replacement
Ngày 27/02/2022 03:04 | Lượt xem: 790

The “Ross procedure” may be a more favourable option for aortic valve replacement among patients under 50 years old than more standard mechanical or biological replacements, according to a study published in the Journal of the American College of Cardiology (JACC).

The research, authored by Ismail El-Hamamsy (Icahn School of Medicine at Mount Sinai, New York, USA) is the first to compare the Ross procedure to the other options, and shows that it leads to improved survival and better outcomes in younger adults, the study team suggests.

“Not only was survival better than after biological or mechanical aortic valve replacement, it was also identical to the matched US general population. To this day, this is the only operation that has ever been shown to restore survival after aortic valve replacement in young adults,” says El-Hamamsy. “This is a huge deal because it demonstrates the impact of valve choice in the long-term. However, there is an important word of caution: the Ross procedure is a more complex operation and should only be performed in Ross centres of excellence. When done in that setting, this represents a major breakthrough for young patients with aortic valve disease, including young women contemplating pregnancy.”

The standard open-heart procedures for aortic repair include mechanical valve replacement—which uses a manufactured valve that requires patients to take life-long blood thinners to prevent stroke, as well as make some lifestyle modifications such as avoiding contact sports that may lead to falls and bruising—or a biological aortic valve replacement from a human or animal donor, which may last up to 20 years, but requires earlier reoperation in younger patients than a mechanical valve.

The Ross procedure is a more complex operation where a surgeon replaces the diseased aortic valve with the patient’s own living pulmonary valve, which is a mirror image of a normal aortic valve. This is the fundamental difference between the Ross procedure and a biological or mechanical valve replacement, which is a critical factor for successful long-term outcomes in patients.

Researchers analysed records of 1,302 patients between 18 and 50 years old who underwent first-time elective aortic valve replacement surgery in California and New York State between 1 January  1997 and 31 December 2014. Patients were equally divided into three categories using propensity-matched analysis to eliminate any baseline differences; one-third of them had the Ross procedure, one-third had biological valve replacement, and the rest had mechanical valve replacement. The retrospective study compared the long-term survival and risk of valve-related complications (including stroke, major bleeding, reoperation, and acute endocarditis) according to the surgical procedure.

Investigators looked at outcomes 15 years post-procedure and found that patient survival was significantly better after the Ross procedure. At 15 years, overall mortality was more than twofold higher if the patients received a biological or mechanical aortic valve versus a Ross procedure.

Furthermore, survival after the Ross procedure (93% survival at 15 years) was identical when compared to people of the same age and sex in the US general population who did not have aortic valve replacement surgery. In terms of valve-related complications, the Ross procedure was associated with a significantly lower risk of stroke or major bleeding than a mechanical valve (3.8% after a Ross procedure versus 13% after a mechanical valve at 15 years).

Similarly, the Ross procedure was associated with significantly fewer reoperations (17% versus 30% at 15 years) and endocarditis—an infection of the heart tissue—than a biological valve (2.3% versus 8.5% at 15 years). At 15 years, however, the risk of reoperation was higher after a Ross procedure than after mechanical valve replacement (17% versus 7.4% at 15 years).

The study also looked at 30-day mortality after the occurrence of any valve-related complication, including stroke, major bleeding, endocarditis, or reoperation. Researchers found the lowest mortality was linked to reoperation (1%), whereas if patients had a stroke, major bleeding, or endocarditis, the associated mortality was at least three times higher (5.6% after a stroke and 13.5% after endocarditis).

“This study demonstrates that while there is a definite risk of reoperation after the Ross procedure, the associated risk is low. In other words, this should be seen as a bump on the road, rather than the end of the road. In contrast, if patients suffer a stroke, haemorrhage, or infection, the consequences are much more dire,” adds El-Hamamsy. “Patients should be given all this data so they can make truly informed decisions about these major life events. Ultimately, the Ross procedure is associated with better survival and fewer complications.”

The authors hope that this will further encourage the development of regional Ross centres of excellence to improve patient access and safety. Furthermore, El-Hamamsy’s team are working on further improving the durability of the Ross procedure so that even fewer patients ever need a reoperation.

Source CardiovascularNews

Duc Tin CLinic

Print Chia sẽ qua facebook bài: Ross procedure “associated with better long-term outcomes” for aortic valve replacement Chia sẽ qua google bài: Ross procedure “associated with better long-term outcomes” for aortic valve replacement Chia sẽ qua twitter bài: Ross procedure “associated with better long-term outcomes” for aortic valve replacement Chia sẽ qua MySpace bài: Ross procedure “associated with better long-term outcomes” for aortic valve replacement Chia sẽ qua LinkedIn bài: Ross procedure “associated with better long-term outcomes” for aortic valve replacement Chia sẽ qua stumbleupon bài: Ross procedure “associated with better long-term outcomes” for aortic valve replacement Chia sẽ qua icio bài: Ross procedure “associated with better long-term outcomes” for aortic valve replacement Chia sẽ qua digg bài: Ross procedure “associated with better long-term outcomes” for aortic valve replacement Chia sẽ qua yahoo bài: Ross procedure “associated with better long-term outcomes” for aortic valve replacement Chia sẽ qua yahoo bài: Ross procedure “associated with better long-term outcomes” for aortic valve replacement Chia sẽ qua yahoo bài: Ross procedure “associated with better long-term outcomes” for aortic valve replacement Chia sẽ qua yahoo bài: Ross procedure “associated with better long-term outcomes” for aortic valve replacement

Tin tức liên quan

CUSTOMER REVIEWS

  • I am Nguyen Thanh Sang, born in 1990. Since the examination and treatment at the clinic Duc Tin, I am very grateful to the Doctor for explaining and sharing about my illness. During the treatment time in the clinic I was very caring staff of the clinic. Now my illness has improved in a good way. Expect more and more clinic to be able to save many patients.

    I sincerely thank you !. Tel: 0938303275

  • Huynh Thi Muoi, born in 1940, was examined and treated at Duc Tin Clinic. I am very pleased about how to serve and care patients of the clinic. The doctor is committed to explaining and sharing with the patient.

    Huynh Thi Muoi sincerely thank you! Phone number: 0972868746

  • As I said Duc Tin surgical clinin is where my family trust, hope to visit. Physicians caring, thoughtful, gentle to the patient. Nurses and staff clinic polite, cheerful and thoughtful. This clinic clean, sterile, so I would love to. Tel: +84949914060.

  • The doctor is very caring, attentive and very gentle nurse, courteous, affable with me. The clinic is clean, comfortable, polite. I enjoyed this faith. Every visit I was very relieved disease. Tel: 0839820792.

  • I was patient, had to clinics of Dr. Le Duc Tin. I see very conscientious doctor patient care, answer any questions and very dedicated staff from the receptionist to the children tested, nursing. Clinics very clean and spacious. I'm very satisfied. Tel: +841227880829.

Search
Customer support

    Phone: (028) 3981 2678
    Mobile: 0903 839 878 - 0909 384 389

TOP