IN.PACT AV drug-coated balloon first and only to show sustained and superior performance compared to PTA through 36 months
Ngày 02/05/2022 07:54 | Lượt xem: 1063

Medtronic announced new randomised controlled data demonstrating the sustained and superior performance of IN.PACT AV drug-coated balloon (DCB) compared to percutaneous transluminal angioplasty (PTA) through 36 months, with no difference in mortality. The data was presented as a Podium 1st at the 2022 Charing Cross (CX) Symposium in London, UK.

“The 36-month data from the IN.PACT AV Access study validates that treatment with the IN.PACT AV DCB can lead to less life disruption and fewer reinterventions for patients for an extended period of time, further reinforcing the results of earlier data milestones,” said Andrew Holden, director of interventional radiology and associate professor of radiology, Auckland University School of Medicine, Auckland, New Zealand. “As the only pivotal DCB study in arteriovenous (AV) access to meet its primary effectiveness endpoint, the IN.PACT AV DCB has shown unrivalled long-term clinical benefits that support its use as the standard of care for AV fistula maintenance in patients with end-stage kidney disease.”

As vessel restenosis limits the ability to use AV fistulas effectively over time, patients often undergo up to three AV fistula maintenance procedures per year to restore function. The need for frequent reinterventions can result in significant disruptions to critical haemodialysis care and increased costs to the healthcare system.

The IN.PACT AV Access study’s three-year data further demonstrates the ability for the IN.PACT AV DCB to extend time to reinterventions from the index procedure by maintaining AV access site patency, therefore maximising a patient’s uninterrupted access to lifesaving dialysis care. Over three years, the IN.PACT AV DCB group demonstrated a continued clinical benefit compared to the PTA control group. Key highlights for this dataset include:

The Kaplan-Meier estimated target lesion primary patency through 36 months was 43.1% in the IN.PACT AV DCB group compared to 28.6% in the PTA control group (log-rank p<0.001).

The Kaplan-Meier estimated access circuit primary patency through 36 months was 26.4% in the IN.PACT AV DCB group compared to 16.6% in the PTA control group (log-rank p<0.001).

The Kaplan-Meier estimated cumulative incidence of all-cause mortality post-vital status update through 36 months was 26.6% in the IN.PACT AV DCB group and 30.8% in the PTA control group (log-rank p=0.709).

“Medtronic is committed to bringing forward technologies that improve the lives of patients undergoing dialysis,” said David Moeller, president of the Peripheral Vascular Health business, which is part of the Cardiovascular Portfolio at Medtronic. “These results demonstrate IN.PACT AV DCB’s ability to significantly reduce the number of reinterventions, as well as the potential to reduce comprehensive care costs.”

Source VascularNews

Duc Tin Clinic

Print Chia sẽ qua facebook bài: IN.PACT AV drug-coated balloon first and only to show sustained and superior performance compared to PTA through 36 months Chia sẽ qua google bài: IN.PACT AV drug-coated balloon first and only to show sustained and superior performance compared to PTA through 36 months Chia sẽ qua twitter bài: IN.PACT AV drug-coated balloon first and only to show sustained and superior performance compared to PTA through 36 months Chia sẽ qua MySpace bài: IN.PACT AV drug-coated balloon first and only to show sustained and superior performance compared to PTA through 36 months Chia sẽ qua LinkedIn bài: IN.PACT AV drug-coated balloon first and only to show sustained and superior performance compared to PTA through 36 months Chia sẽ qua stumbleupon bài: IN.PACT AV drug-coated balloon first and only to show sustained and superior performance compared to PTA through 36 months Chia sẽ qua icio bài: IN.PACT AV drug-coated balloon first and only to show sustained and superior performance compared to PTA through 36 months Chia sẽ qua digg bài: IN.PACT AV drug-coated balloon first and only to show sustained and superior performance compared to PTA through 36 months Chia sẽ qua yahoo bài: IN.PACT AV drug-coated balloon first and only to show sustained and superior performance compared to PTA through 36 months Chia sẽ qua yahoo bài: IN.PACT AV drug-coated balloon first and only to show sustained and superior performance compared to PTA through 36 months Chia sẽ qua yahoo bài: IN.PACT AV drug-coated balloon first and only to show sustained and superior performance compared to PTA through 36 months Chia sẽ qua yahoo bài: IN.PACT AV drug-coated balloon first and only to show sustained and superior performance compared to PTA through 36 months

Tin tức liên quan

CUSTOMER REVIEWS

  • I am Nguyen Thanh Sang, born in 1990. Since the examination and treatment at the clinic Duc Tin, I am very grateful to the Doctor for explaining and sharing about my illness. During the treatment time in the clinic I was very caring staff of the clinic. Now my illness has improved in a good way. Expect more and more clinic to be able to save many patients.

    I sincerely thank you !. Tel: 0938303275

  • Huynh Thi Muoi, born in 1940, was examined and treated at Duc Tin Clinic. I am very pleased about how to serve and care patients of the clinic. The doctor is committed to explaining and sharing with the patient.

    Huynh Thi Muoi sincerely thank you! Phone number: 0972868746

  • As I said Duc Tin surgical clinin is where my family trust, hope to visit. Physicians caring, thoughtful, gentle to the patient. Nurses and staff clinic polite, cheerful and thoughtful. This clinic clean, sterile, so I would love to. Tel: +84949914060.

  • The doctor is very caring, attentive and very gentle nurse, courteous, affable with me. The clinic is clean, comfortable, polite. I enjoyed this faith. Every visit I was very relieved disease. Tel: 0839820792.

  • I was patient, had to clinics of Dr. Le Duc Tin. I see very conscientious doctor patient care, answer any questions and very dedicated staff from the receptionist to the children tested, nursing. Clinics very clean and spacious. I'm very satisfied. Tel: +841227880829.

Search
Customer support

    Phone: (028) 3981 2678
    Mobile: 0903 839 878 - 0909 384 389

TOP